Type: ZW, snap action double pole contact miniature pressure switch, plastic fitting, DPDT contact

 DIMENSIONS

Uses: High electrical rating, for 250V .

Main applications: Pressure sensing on water heaters, boilers, and electrical appliances.

Membranes: EPDM, dia 22 mm. Silicone or NBR on request Double membrane on request.

Fluid: water or air.

Fitting: Plastic.

Pressure: positive.

Housing: PA66, UL94 VO.

Contact: DPDT, snap action. NO or NC contacts available with MOQ.

Electrical rating: Depends on microswitch operating force that is linked to the electrical rating.

– Standard rating micro-switch (medium and high pressure calibration only): 16A 125/250VAC;1/2HP 125VAC; 3/4HP 250VAC.

– High rating micro-switch (medium and high pressure calibra­tion only): 2HP 240V, 21(8) A 240V (UL, CSA VDE switch).

– Low force micro-switch (set points less than 200 mbar): 1/4HP 6(1) A 240V ( UL, CSA VDE switch).

– On request: up to 25A 250V.

Action: momentary.

Set point calibration: factory calibrated and sealed, not field adjustable. On request it is possible to have staggered calibration.

Set point calibration limits: from 100 to 1500 mbar.

Electrical connection: 6.35 x 0.8 mm quick connect terminals.

Maximum pressure: 4 bars (58 PSI).

Ambient temperature limits: 0 to 85°C.

 

Available pressure inlet fittings

References (with SPDT contact):

Pressure inlet Standard rating micro- switch

(Calibration: 800 mbar)

Low pressure micro-switch

(Calibration 150 mbar)

High rating micro-switch

(Calibration 800 mbar)

1/8″ NPT ZW2K28U1UH000000 ZW2728U50A500000 ZW2K28U6UH000000
1/4″ BSPP ZW2K2QU1UH000000 ZW272QU50A500000 ZW2K2QU6UH000000
M10 x 1 ZW2K2MU1UH000000 ZW272MU50A500000 ZW2K2MU6UH000000
Snap in fitting, 2 grooves dia 7.8 ZW2K2TU1UH000000 ZW272TU50A500000 ZW2K2TU6UH000000
Snap in fitting, 1 groove dia 10 ZW2K2ZU1UH000000 ZW272ZU50A500000 ZW2K2ZU6UH000000
Snap in fitting, 1 spout dia 6mm ZW2K2AU1UH000000 ZW272AU50A500000 ZW2K2AU6UH000000
  Other set point values: replace H00 in the product reference by the requested value in mbar. Other set point values: replace A50 in the product reference by the requested value in mbar. Other set point values: replace H00 in the product reference by the requested value in mbar.

 

PDF