Type ZF: Slow action contact miniature vacuum switch, 6.35 x 0.8 mm terminals, metal fitting SPNC contact

Uses: Low voltage, high sensivity

Main applications: Electronic printed circuit. This vacuum switch is more sensible than snap action models and can be calibrated at lower pressure values. Very small differential.

Membranes: EPDM, dia 22 mm. Silicone or NBR on request

Fluid: air or water

Fitting: Brass (stainless steel on request)

Pressure: negative (Vacuum)

Housing: PA66, UL94 VO

Contact: single pole normally closed at atmospheric pressure, slow break.

Electrical rating:

– Silver contact: max 1A 250V

– Gold plated contact: max 100 mA, 24V

Action: momentary, open on vacuum increase (=decrease of absolute pressure).

Set point calibration: factory calibrated and sealed, not field adjustable

Set point calibration limits (relative pressure): standard calibration minus 50mbar, other values are achievable from minus 20 to minus 200 mbar

Electrical connection: two 6.35 x 0.8 mm quick connect terminals

Maximum pressure: 2 bars (29 PSI)

Maximum vacuum: minus 500 mbar (relative pressure)

Ambient temperature limits: 0 to 85°C

 

Available pressure inlet fittings

 

References ( with calibration at minus 50 mbar and brass fitting):

Pressure inlet              Silver contact Gold plated contact
1/8’’ NPT ZF2X1REA05000000 ZF2X1REG05000000
1/8’’BSPT ZF2X1PEA05000000 ZF2X1PEG05000000
1/8’’BSPP ZF2X1LEA05000000 ZF2X1LEG05000000
1/4’’ NPT ZF2X1CEA05000000 ZF2X1CEG05000000
1/4’’ BSPT ZF2X1SEA05000000 ZF2X1SEG05000000
1/4’’ BSPP ZF2X12EA05000000 ZF2X12EG05000000
Smooth spout dia 4 mm ZF2X13EA05000000 ZF2X13EG05000000
Spout dia 6 mm ZF2X17EA05000000 ZF2X17EG05000000
Fluted spout dia 6 mm ZF2X1JEA05000000 ZF2X1JEG05000000
Barbed spout dia 10 mm ZF2X19EA05000000 ZF2X19EG05000000

Other set point values: replace 050 in the product reference by the requested value in mbar

 