Type YF83NC: Adjustable electronic manual reset limiters for immersion heaters

 

Applications

 

-Equipment requesting a very strong resistance to water ingress. The transparent cover allows to visualize the set point and the 2 pilot lights

Fully wired electronic temperature control sub assembly for direct mounting on immersion heater elements, 1”1/2 or M45x2 with double thread or rotation ring.

Applications in high temperature safety in usual industrial applications and environments, non-hazardous areas.

 

Housing: Protection class IP 66 upon EN 60529 (waterproof spray water under high pressure and sea splashes, totally dust tight). Body in black PA66, fiber glass reinforced. The transparent polycarbonate cover can be unscrewed by hand, but it is also possible to use a hook spanner.  A removable adapter is screwed at the bottom of the enclosure. It fits the usual immersion heater fittings. Mechanical impact resistance : IK10. High UV resistance.

Set point adjustment:  By °C printed knob. All types have an adjustable rotation limit system located inside the knob that allows reducing the set point adjustment span. °F printed knobs available as an option.

Operation:  Microprocessor electronic thermostat, manual reset high temperature limiter

Set point adjustment ranges: 4-40°C (40-105°F); 30-90°C (85-195°F); 30-110°C (85-230°F).

Differential: Manual reset differential is preset at the minimum value, but can be increased with a potentiometer located under the set point adjustment knob.

Sensing element: The  5x 30mm NTC sensor (10KOhms @25°C) goes out by the bottom of the enclosure to fit in the immersion heater pocket.

Pilot lights: One pilot light visualizes the thermostat contact output position. The other visualizes the power supply input. Phase and line 230V power supply is mandatory for these pilot lights.

Cable input and output: Two M20 cable glands, built-in black PA66. One of them is closed.

Electrical connections:  Inside, on screw terminal connection block.

Earthing:  Internal screw terminal and 1.5mm² FEP insulated wire with round hole terminals for the immersion heater.

Mounting: By the immersion heater thread or by 2 legs with holes for screws dia. 4 to 5 mm, 114  mm distance.

Identification: Identification label on backside.

Contact: SPNC. 16A (2.6), 250VAC. Contact open on temperature rise.

Electrical life: >100.000 cycles. 

Minimum storage temperature: -35°C (-30°F)

Maximum ambient temperature: 60°C (140°F)

For more technical information ask 2PE2N6 thermostat technical data sheet.

 

PDF

2D&3D Drawing

Main references

Temperature adjustment ranges

°C (°F)

References with SPNC contact, open on temperature rise NTC sensor cable length (C, mm) Minimum differential °C (°F)
4-40°C (40-105°F) YF83NC04040118UJ 110 0,5~0,8°C (0.9~1.4°F)
4-40°C (40-105°F) YF83NC04040178UJ 170 0,5~0,8°C (0.9~1.4°F)
4-40°C (40-105°F) YF83NC04040238UJ 230 0,5~0,8°C (0.9~1.4°F)
4-40°C (40-105°F) YF83NC04040308UJ 300 0,5~0,8°C (0.9~1.4°F)
4-40°C (40-105°F) YF83NC04040458UJ 450 0,5~0,8°C (0.9~1.4°F)
4-40°C (40-105°F) YF83NC04040608UJ 600 0,5~0,8°C (0.9~1.4°F)
30-90°C (85-195°F) YF83NC30090118UJ 110 0,5~0,8°C (0.9~1.4°F)
30-90°C (85-195°F) YF83NC30090178UJ 170 0,5~0,8°C (0.9~1.4°F)
30-90°C (85-195°F) YF83NC30090238UJ 230 0,5~0,8°C (0.9~1.4°F)
30-90°C (85-195°F) YF83NC30090308UJ 300 0,5~0,8°C (0.9~1.4°F)
30-90°C (85-195°F) YF83NC30090458UJ 450 0,5~0,8°C (0.9~1.4°F)
30-90°C (85-195°F) YF83NC30090608UJ 600 0,5~0,8°C (0.9~1.4°F)
30-110°C (85-230°F) YF83NC30110118UJ 110 0,5~0,8°C (0.9~1.4°F)
30-110°C (85-230°F) YF83NC30110178UJ 170 0,5~0,8°C (0.9~1.4°F)
30-110°C (85-230°F) YF83NC30110238UJ 230 0,5~0,8°C (0.9~1.4°F)
30-110°C (85-230°F) YF83NC30110308UJ 300 0,5~0,8°C (0.9~1.4°F)
30-110°C (85-230°F) YF83NC30110458UJ 450 0,5~0,8°C (0.9~1.4°F)
30-110°C (85-230°F) YF83NC30110608UJ 600 0,5~0,8°C (0.9~1.4°F)

°F printing: replace last character (J) by K