Home / Heating equipment / Type: 9STM. Immersion heater with 130mm x 130mm x 190mm plastic enclosure.
Fittings from 1″1/2 to M77x2. With control thermostat. With or without and manual reset. Power up to 21kW with one built-in power relay. Heating elements dia. 8, 10 and 12 mm.
Main applications: Industrial liquid heating, hot water circuits, containers and buffer tanks.
These immersion heaters are designed for medium power applications, requesting power relays. They are fitted with one relay, 3 pole, 32A res. They have in standard two pilot lights and one main switch.
They are intended for indoor use.
These enclosures have a 40mm offset to go through tank thermal insulation.
They exist in:
– 6 standard power levels: 4kW; 6kW; 8kW; 10kW; 12kW; 14kW.
(on request, it is possible to reach 21kW with dia.12mm heating elements).
– 2 types of standard fittings with dia. 8mm heating elements: 1″1/2; M45x2.
– 3 types of standard fittings with dia. 10mm heating elements: 2″, 2″1/2; M77x2.
– 2 types of surface load density: 5W/cm² and 10W/cm². See technical introduction to optimize the surface load.
Heater tube material: 8mm dia. or 10 mm dia. AISI 304 or Incolloy 800 (AISI 316; AISI 321; Incolloy 825 on request).
Fitting material: brass, swiveling on housing, brazed on tubes. (AISI 304 or AISI 316, TIG welded, or brazed, models are available on request). Supplied without gasket and without nut. See accessories below.
Thread: 1″1/2 BSPP (ISO 228), and metric thread M45x2 (dia. 8 heating elements), and 2″,2″1/2, M77x2 (dia. 10mm heating elements).
Enclosure: 130 mm x 130 mm, 150mm height, black PA66 fiberglass reinforced. Silicone foam gasket. Stainless steel cover screws with locking nuts.
Ingress protection class: Water and dust: IP54; shock resistance: IK 8 (with metal cable glands and M25 metal plug).
Temperature control: by 30-90°C (85-195°F) bulb and capillary thermostat, with outside knob access. Thermostat shaft has a waterproof gasket. Other temperature ranges available. See options hereunder.
Cable gland: M25, PA66. Mounted on a removable board for easier wiring access. A second hole for M25 cable gland is available, closed by a screwed cap.
Thermowell: one thermowell in AISI304, dia.10 mm, for M45 and 1″1/2 fittings, 2 thermowells for larger sizes.
Heating elements connections: terminals with stainless steel screw, nut and stainless steel washer.
Designed for applications in three-phase with neutral, however, these devices are equipped with straps for switching to single-phase supply. This change must be made by the professional technical staff able to calculate and observe the maximum permissible intensities on power relays.
Power supply connection:
– on built in connection block, 6x10mm² for power connection and 2×2.5mm² for optional external remote control.
Support grid: 1 grid AISI 304 for lengths from 400 to 600mm, 2 grids above.
Not heating immersed zone: 50mm.
Surface load: standard 5 W/cm² or 10 W/cm², others values on request.
Voltage: three phase 380-400V (Star connection with neutral). Single pole 230V is possible.
Standard equipment:
– Manual reset thermostat, reset access by M25 screwed cap, preset at 100°C (212°F).
– Main power switch.
– Large size (dia. 16mm) LED pilot lights. Green illuminated when heating is on. Red illuminated when manual reset is trigged.
Variants on request:
– Thermostat knob accessible under the cover by a M25 removable plug (on request).
– 4-40°C, 0-60°C or 30-110°C thermostats. Higher range on request.
– 4-40°C (40-105°F) temperature range with manual reset at 60°C (140°F).
– 0-60°C (32-140°F) temperature range with manual reset at 80°C (176°F).
– 30-110°C (85-230°F) temperature range with manual reset at130°C (266°F).
– Thermal cut out located inside immersion heater pocket.
– 400V power supply without neutral: consult us.
Electric Wiring
Temperature control thermostat Temperature control thermostat and manual reset thermostat
Main references
5W/cm², with 30-90°C (85-195°F) thermostat, external knob, without manual reset.
1″1/2* brass fitting, dia. 8mm heating elements | 2″1/2** brass fitting, dia. 10mm heating elements | ||||
Power | 4kW | 6kW | 8kW | 10kW | 12kW |
Length (mm) | 570 | 840 | 1100 | 1100 | 1300 |
AISI 304 Reference | 9STMA5QT040U8570 | 9STMA5QT060U8840 | 9STMA5QT080U8J00 | 9STMA7QT100U1K00 | 9STMA7QT120U1M00 |
Incolloy 800 reference | 9STMA5QT040UK570 | 9STMA5QT060UK840 | 9STMA5QT080UKJ00 | 9STMA7QT100ULK00 | 9STMA7QT120ULM00 |
110W/cm², with 30-90°C (85-195°F) thermostat, external knob, without manual reset.
1″1/2* brass fitting, dia. 8mm heating elements | 2″1/2** brass fitting, dia. 10mm heating elements | ||||
Power | 4kW | 6kW | 8kW | 10kW | 12kW |
Length (mm) | 300 | 440 | 570 | 540 | 660 |
AISI 304 Reference | 9STMA5QT040U8300 | 9STMA5QT060U8440 | 9STMA5QT080U8570 | 9STMA7QT100U1540 | 9STMA7QT120U1660 |
Incolloy 800 reference | 9STMA5QT040UK300 | 9STMA5QT060UK440 | 9STMA5QT080UK570 | 9STMA7QT100UL540 | 9STMA7QT120UL660 |
5W/cm², with 30-90°C (85-195°F) adjustable thermostat, external knob. Manual reset at 100°C (212°F)
Threads and heating elements diameters | 1″1/2* brass fitting, dia. 8mm heating elements | 2″1/2** brass fitting, dia. 10mm heating elements | |||
Power | 4kW | 6kW | 8kW | 10kW | 12kW |
Length (mm) | 570 | 840 | 1100 | 1100 | 1300 |
AISI 304 Reference | 9STMA5QT040U857N | 9STMA5QT060U884N | 9STMA5QT080U8J0N | 9STMA7QT100U1K0N | 9STMA7QT120U1M0N |
Incolloy 800 reference | 9STMA5QT040UK57N | 9STMA5QT060UK84N | 9STMA5QT080UKJ0N | 9STMA7QT100ULK0N | 9STMA7QT120ULM0N |
10W/cm², with 30-90°C (85-195°F) adjustable thermostat, external knob. Manual reset at 100°C (212°F)
Threads and heating elements diameters | 1″1/2* brass fitting, dia. 8mm heating elements | 2″1/2** brass fitting, dia. 10mm heating elements | ||||
Power | 4kW | 6kW | 8kW | 10kW | 12kW | 14kW |
Length (mm) | 300 | 440 | 570 | 540 | 660 | 770 |
AISI 304 Reference | 9STMA5QT040U830N | 9STMA5QT060U844N | 9STMA5QT080U857N | 9STMA7QT100U154N | 9STMA7QT120U166N | 9STMA7QT120U177N |
Incolloy 800 reference | 9STMA5QT040UK30N | 9STMA5QT060UK44N | 9STMA5QT080UK57N | 9STMA7QT100UL54N | 9STMA7QT120UL66N | 9STMA7QT120UL77N |
* In dia. 8mm: M45x2 brass fitting instead of 1″1/2, replace A5 by A9 in the reference.
** In dia. 10mm: 2″ brass fitting instead of 2″1/2, replace A7 by A6 in the reference. M77x2 brass fitting instead of 2″1/2, replace A7 by A8 in the reference.
References of accessories in option (not included in the product, must be ordered separately):
Nuts
Gaskets
Other accessories and drawings: see last section of this catalogue.