Type 9CL:Fan heaters, 110mm compact range,Downward blowing models

Fan heaters, 110mm compact range

Downward blowing models

Type 9CL

Main applications

These heavy duty fan heaters, downward blowing, are characterized by their very small size, and are designed for professional, commercial or industrial applications.

They must be mounted on a vertical wall, at more than 40cms from the floor or any board.

Top side air inlets are equipped with a baffle protecting the fans against liquid drops or particle inlet.

They are equipped with 3 ultra-thin fans, with a 2 pole, illuminated on-off switch, an adjustable control thermostat and a safety thermostat.

Although their heating elements are shielded and sealed, their control box is not waterproof, and they should not be used outdoors. Their insulation class 1 does not allow to use them in bathroom and in all places requiring Class II insulation. They are not designed for use in hazardous environments.

They exist with painted steel or stainless steel frame.

The main applications are heating of professional workshops, heating small volumes such as bungalows, cranes cabins, construction equipment, wagons or locomotives cockpit, technical rooms, ovens, containers, dryers.

Main features

Dimensions: 2 body lengths: 410 or 710mm

Ingress protection: IP44

Heaters: 3 finned elements in 304L stainless steel. Fins 25x50mm 304 stainless steel. Surface load 3W/cm²

Frame material: 0.8mm thick sheet, high strength (Withstands +100kg distributed load), two versions:

– Galvanized steel sheet with black epoxy paint

– 304 stainless steel sheet.

Fans: 3 fans of 80 x 80mm, flow 3 x 30m3/h. L10 life expectancy: 50.000 h (>5 years) at 25ºC. L10 refers to the time at which statistically, 90% of the fan will still be operative. Life expectancy is reduced by about 50% when ambient temperature rises to 50-70°C.

Controls:  adjustable bulb and capillary control thermostat, range 4 to 40°C, and fail safe high limit manual reset thermostat for protection against air outlet obstruction or fans failure. (Both controls protected against water ingress)

Main switch: 2 pole, on off, illuminated, with water ingress protection boot

Electrical connection: by grounded euro plug, 2 meters, 3×1.5mm²

Mounting: 2 wall mounting legs

Voltage: 230V, 50/60Hz. Other voltages available on request.

Power: 1500W (410mm)  and  3000W (710mm)

Ambient temperature : -20 to +60 ° C

Net weight: 4.6kg (410mm) ; 6.8kg (710mm)

Option: customization accepted

References with 230V power supply

Black painted steel frame

304 stainless steel frame
References Power (W) L References Power (W)

L

9CL14033023150HB

1500 410 9CL14033023150H4 1500 410
9CL17033023300HB 3000 710 9CL17033023300H4 3000

710